Research

Analyzer Services

Master
Content

We offer technician assisted Cell Analysis. This service is available Monday through Friday from 8 a.m. to 6 p.m.

Request an assisted analysis appointment.

Heading

Consultation

Content

Consultation regarding experimental design, panel design, and data analysis is available. Sign up for a consultation here.

Heading

Tubes Used For Analysis

Content

Only BD polystyrene FACS tubes.

The BD tubes below work on all cytometers here in the CCSC and are available for purchase:

  • 352052 (5 mL tubes with no lid). $12.50/pack of 125 tubes
  • 352054 (5 mL tubes with lids). $15/pack of 125 tubes
  • 352235 (5 mL filter-cap tubes). $25/pack of 25 tubes
Heading

Aurora (T109)

Content
  • Benchtop spectral cytometer
  • 407 (Violet), 488 (Blue), 561 (Yellow-Green), and 635 (Red) nm lasers UV coming soon
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 54 colors plus Forward Scatter and Side Scatter
  • Option to subtract autofluorescence
Heading

FACSymphony (T109)

Content

This instrument can detect 30+ different markers of interest on a single cell, allowing a more in-depth look at the tumor environment, signal transduction pathways (Phosflow), transcriptional nodes, tetramer applications, cell differentiation, cell division, effector function, and cell death.

  • Benchtop cytometer
  • 355 (UV), 407 (Violet), 488 (Blue), 561 (Yellow-Green), and 635 (Red) nm lasers
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 29 colors plus Forward Scatter and Side Scatter
Heading

Helios and Hyperion (T219)

Content

Different from the traditional fluorescence based cytometer, the Helios uses metals-tagged antibodies to label markers of interest in cells. The high purity and choice of metal isotopes provide minimal background noise from signal overlap or endogenous cellular components, plus 135 available detection channels ensure an ongoing ability to add more parameters, enabling you to fully study the functional complexity of biological systems at the single-cell level.

  • The Hyperion Imaging System allows for simultaneous interrogation of 4-37 protein markers using a plate platform so that adherent cells can be imaged and analyzed without processing them into single cell suspension.
  • 135 possible detectors with 40+ metal isotopes available for tagging
Heading

Cytek ImageStreamX Mark II (T109)

Content

This instrument produces multiple high-resolution images of every cell directly in flow, including brightfield and darkfield (SSC), and up to 10 fluorescent markers with sensitivity exceeding conventional flow cytometers. Resolution options of 20X, 40X, and 60X.

  • Benchtop Image Scanning cytometer
  • 405 (Violet), 488 (Blue), 561 (Yellow-Green), and 642 (Red) nm lasers
  • Total of 10 colors plus Side Scatter and Brightfield
Heading

LSRII (T103)

Content
  • Benchtop cytometer
  • 355 (UV), 407 (Violet), 488 (Blue), 561 (Yellow-Green), and 635 (Red) nm lasers
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 16 colors plus Forward Scatter and Side Scatter
Heading

LSRII (M902)

Content
  • Benchtop cytometer
  • 355 (UV), 407 (Violet), 488 (Blue), and 635 (Red) nm lasers
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 14 colors plus Forward Scatter and Side Scatter
Heading

LSRFortessa (T103)

Content
  • Benchtop cytometer
  • 355 (UV), 407 (Violet), 488 (Blue), 561 (Yellow-Green), and 635 (Red) nm lasers
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 17 colors plus Forward Scatter, Forward Scatter PMT, and Side Scatter
Heading

CantoII Yellow-Green Carousel (T103)

Content
  • Benchtop cytometer
  • 488 (Blue), 561 (Yellow-Green) and 635 (Red) nm lasers
  • Carousel option for automated tube loading of up to 160 tubes in 4 carousels
  • Total of 8 colors plus Forward Scatter and Side Scatter
Heading

CantoII Violet HTS (T103)

Content
  • Benchtop cytometer
  • 407 (Violet), 488 (Blue) and 635 (Red) nm lasers
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 8 colors plus Forward Scatter and Side Scatter
Heading

Attune Acoustic Focusing Cytometer (T103)

Content
  • Benchtop cytometer
  • 407 (Violet) and 488 (Blue) nm lasers
  • High Throughput Sample Option (with the ability to run 96 well plates)
  • Total of 6 colors plus Forward Scatter and Side Scatter
Heading

Sample Restrictions

Content

Cell populations to be analyzed or sorted cannot contain radionuclides or radioactive substances (eg, P-32).